Equipments - Flow Split

Use the Flow Split to split the inlet stream into two outlet streams. Check First and/or Second Outlet Flow Given. Or specify the total flow to the first outlet stream or the flow of liquor, solids and gas to the first outlet stream.

What do you want to see?

 

Data Description

Data Unit Description
Set Item Type Native
Equipment Properties First Outlet Flow Given If checked (True) the total flow in the first outlet stream is given.
Second Outlet Flow Given If checked (True) the total flow in the second outlet stream is given.
First Outlet Total Mass Flow lbs/hr The total flow in the first outlet stream.
First Outlet Liquor Mass Flow lbs/hr The flow of liquor in the first outlet stream.
First Outlet Solids Mass Flow lbs/hr The flow of solids in the first outlet stream.
First Outlet Gas Mass Flow lbs/hr The flow of gas in the first outlet stream.
Top of Page

Equipment Properties

Top of Page

Example of using equipment

Top of Page

Method&Equations

If the First Outlet Flow Given is checked (True) the flow in the second outlet is calculated as the difference between the inlet flow and the first outlet flow. The same occurs if the Second Outlet Flow Given is checked.

          Second Outlet Flow=Inlet Flow-First Outlet Flow

          First Outlet Flow=Inlet Flow-Second Outlet Flow

If both the First and Second Outlet Flow Given are checked the model acts as a reverse mixer: the inlet flow is the sum of the first and second outlet flows.

        Inlet Flow=First Outlet Flow + Second outlet Flow

In all cases the outlet's state and composition are set to the inlet state and composition.

Top of Page

Warnings

Zero inlet flow!

No enough flow in inlet to meet the request!

Top of Page

Errors

Missing Stream(s)!

Top of Page